The cursor will move back to the "tens" digit position. The cursor will move to the "ones" digit position. Set the current address to "00": Press to clear the current "tens" digit. NOTE: The keypad will not enter address mode if the panel to which it is connected is in programming mode. You must power down, power up and start address mode again. If 10 seconds have passed with no key entry, the keypad automatically exits address mode. (If unable to enter address mode, power up and try again.) The current keypad address will be displayed, and the cursor will be under the "tens" digit. Within 60 seconds of power-up, press and hold down the and keys at the same time for 3 seconds. To change the keypad's address, do the following: 1. The keypad can either be set for an address of 00-30, or to the non-addressable mode (31). NOTE: TO REMOVE CASE BACK PUSH IN THE TWO MOUNTING SNAPS LOCATED ALONG THE BOTTOM OF THE KEYPAD AND LIFT UP.įor operating instructions, see the User Guide for the control panel used with this keypad. These labels can be placed on or next to the keys to identify each key's function for the end user (as determined by the control panel's capability and programming see the control's instructions). Reattach the keypad to its case back.Ī set of adhesive-backed labels with some typical function symbols (i.e., fire, police, personal emergency, etc.) is provided. See the control panel’s Installation and Setup Guide for more complete details. Function Keys A or and B or and C or and D See the control's instructions for details.įunction keys must be held down for at least 2 seconds to activate an alarm key pairs are activated immediately. These keys may be programmed for panic alarms or other special functions such as macros. LED Red Green Function Lights when the system is armed in any mode Lights when the system is "ready" to be armed. The following table shows the LEDs and their functions: Model 6150 6160 Fixed Word Display X X 2-line Alpha Display 2-digit Zone Identifier X X Custom Zone Descriptors The keypads have the following display features:

honeywell alarm keypad m7240

Honeywell alarm keypad m7240 series#

Wiring Table (All Keypads) Keypad Control Panel Data In Wire Color Green Black Red Yellowįor ULC installations, the VISTA-128BP/VISTA-250BP Series must be used with the ADEMCO 6160 keypad. If daisy-chained configuration is required, pig-tail wires together so that only one wire is terminated under the screw. NOTE: No more than one wire per terminal may be connected.

honeywell alarm keypad m7240

Wire directly from the keypad’s terminal block to the terminal block on the control panel. Mount the case back to a wall or electrical box. Route wiring from the control panel through the opening in the case back. Refer to Figure 1 for location of the case back release snaps and locking tabs. Insert the screwdriver in the side of the keypad (between the front and back case) and gently twist to release the side locking tab. Push the two case release snaps at the bottom of the keypad with the blade of a medium screwdriver (this will push in the release snap), then pull that side of the case back away. The keypads can be surface mounted directly to a drywall, or to a single- or double-gang electrical box. Supervised by control panel (if supported). The keys on the keypads are continuously backlit for convenience. The ADEMCO 6150 and ADEMCO 6160 are addressable Remote Keypads designed for use with ADEMCO control panels. Note: Permanent display backlighting is an option on some controls (see the control's instructions for details). Keypad Features Backlit Display Dedicated Function Keys Built-in Sounder Piezo Speaker ADEMCO 6150 Fixed-Word (see note) ADEMCO 6160 2-Line Alpha (see note)









Honeywell alarm keypad m7240